Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 31, 2021, 10:00 AM
  • P12942_15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5_15 0743_15 0742_POST_SI_Memo.mpg

Date
08/31/2021
W/O
Weather
Dry
Operator/Surveyor
O.QUEZADA
Sewer ID
Z00593
PipeID
P12942
Time
3:00 AM
Certificate
1234
System Owner
1
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
POST
Project
ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
15 in.
Upstream MH
15 0743
Downstream MH
15 0742
Dir. of Survey
Downstream
Length Surveyed
350.1 ft.
Total Length
350.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0743 to 15 0742
MH: 15 0743MH: 15 0742downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST VIDEO69.4 ft. TFA - Tap Factory Made Active, at 03 o'clock, -, within 8 inches of joint: YES, 6"74.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"172.6 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"175.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"258.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"341.5 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"350.1 ft. AMH - Downstream Manhole, Survey Ends - POST VIDEO

Observations (8)

DistanceCodeObservation
0AMHPOST VIDEO
341.5TBA
350.1AMHPOST VIDEO
175.8TFA
69.4TFA
74.5TFA
172.6TFA
258.8TFA

Properties (3)

customer
1
datetime
2021-08-31T03:00:00-07:00
is_lateral_inspection
false