Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 2, 2021, 10:00 AM
  • P12940_15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5_15 0741_15 0740_POST_SI_Memo.mpg

Date
09/02/2021
W/O
Weather
Dry
Operator/Surveyor
O.QUEZADA
Sewer ID
Z00593
PipeID
P12940
Time
3:00 AM
Certificate
1234
System Owner
1
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
09
Purpose
POST
Project
ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
15 in.
Upstream MH
15 0741
Downstream MH
15 0740
Dir. of Survey
Downstream
Length Surveyed
350.8 ft.
Total Length
350.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0741 to 15 0740
MH: 15 0741MH: 15 0740downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST VIDEO64.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"71.7 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"110.2 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"154.3 ft. TFB - Tap Factory Made Abandoned, at 02 o'clock, -, within 8 inches of joint: YES, 6"223.9 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"226.2 ft. TBA - Tap Break-In Active, at 03 o'clock, -, within 8 inches of joint: YES, 6"350.8 ft. AMH - Downstream Manhole, Survey Ends - POST VIDEO

Observations (8)

DistanceCodeObservation
223.9TBA
154.3TFB
64.7TFA
71.7TBA
110.2TFA
350.8AMHPOST VIDEO
226.2TBA
0AMHPOST VIDEO

Properties (3)

customer
1
datetime
2021-09-02T03:00:00-07:00
is_lateral_inspection
false