Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 16, 2021, 01:00 PM
  • P12972_15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5_15 0771_15 0770_POST_SI_Memo.mpg

Date
11/16/2021
W/O
Weather
Dry
Operator/Surveyor
O.QUEZADA
Sewer ID
Z00593
PipeID
P12972
Time
5:00 AM
Certificate
123457
System Owner
1
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA10
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
POST
Project
ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
15 in.
Upstream MH
15 0771
Downstream MH
15 0770
Dir. of Survey
Downstream
Length Surveyed
401.3 ft.
Total Length
401.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0771 to 15 0770
MH: 15 0771MH: 15 0770downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST VIDEO54.4 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"91 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"102.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"106 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"158.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"163.8 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"281.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"312.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"401.3 ft. AMH - Downstream Manhole, Survey Ends - POST VIDEO

Observations (10)

DistanceCodeObservation
91TBA
0AMHPOST VIDEO
163.8TFA
281.7TFA
106TFA
312.1TFA
54.4TBA
102.8TFA
401.3AMHPOST VIDEO
158.5TFA

Properties (3)

customer
1
datetime
2021-11-16T05:00:00-08:00
is_lateral_inspection
false