Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 24, 2021, 01:00 PM
  • P12969_15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5_15 0768_15 0767_POST_SI_Memo.mpg

Date
11/24/2021
W/O
Weather
Dry
Operator/Surveyor
O.QUEZADA
Sewer ID
Z00593
PipeID
P12969
Time
5:00 AM
Certificate
123456
System Owner
1
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
POST
Project
ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
15 in.
Upstream MH
15 0768
Downstream MH
15 0767
Dir. of Survey
Downstream
Length Surveyed
201.3 ft.
Total Length
201.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0768 to 15 0767
MH: 15 0768MH: 15 0767downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST VIDEO76 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"76 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"116.1 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"120.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"201.3 ft. AMH - Downstream Manhole, Survey Ends - POST VIDEO

Observations (6)

DistanceCodeObservation
116.1TFA
76TBA
201.3AMHPOST VIDEO
76TBA
0AMHPOST VIDEO
120.1TFA

Properties (3)

customer
1
datetime
2021-11-24T05:00:00-08:00
is_lateral_inspection
false