Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 6, 2021, 12:00 PM
  • P12965_15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5_15 0764_15 0763_POST_SI_Memo.mpg

Date
11/06/2021
W/O
Weather
Dry
Operator/Surveyor
O.QUEZADA
Sewer ID
Z00593
PipeID
P12965
Time
5:00 AM
Certificate
12345
System Owner
1
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
08
Purpose
POST
Project
ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
15 in.
Upstream MH
15 0764
Downstream MH
15 0763
Dir. of Survey
Downstream
Length Surveyed
352.8 ft.
Total Length
352.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0764 to 15 0763
MH: 15 0764MH: 15 0763downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST VIDEO79.5 ft. TFA - Tap Factory Made Active, at 11 o'clock, -, within 8 inches of joint: YES, 6"82.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"122.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"126.2 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"167.9 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"167.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"266.4 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"352.8 ft. AMH - Downstream Manhole, Survey Ends - POST VIDEO

Observations (9)

DistanceCodeObservation
79.5TFA
167.9TFA
82.3TFA
122.5TFA
0AMHPOST VIDEO
352.8AMHPOST VIDEO
167.9TBA
266.4TFA
126.2TFA

Properties (3)

customer
1
datetime
2021-11-06T05:00:00-07:00
is_lateral_inspection
false