Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 17, 2021, 02:00 PM
  • P12962_15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5_15 0761_15 0760_POST_SI_Memo.mpg

Date
11/17/2021
W/O
Weather
Dry
Operator/Surveyor
O,QUEZADA
Sewer ID
Z00593
PipeID
P12962
Time
6:00 AM
Certificate
12345
System Owner
1
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
08
Purpose
POST
Project
ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
15 in.
Upstream MH
15 0761
Downstream MH
15 0760
Dir. of Survey
Downstream
Length Surveyed
329.8 ft.
Total Length
329.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0761 to 15 0760
MH: 15 0761MH: 15 0760downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST VIDEO91.3 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"159.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"164.5 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"226.1 ft. TBA - Tap Break-In Active, at 12 o'clock, -, within 8 inches of joint: YES, 6"252.3 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"303.7 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"329.8 ft. AMH - Downstream Manhole, Survey Ends - POST VIDEO

Observations (8)

DistanceCodeObservation
252.3TFA
226.1TBA
164.5TFA
0AMHPOST VIDEO
303.7TFA
329.8AMHPOST VIDEO
91.3TBA
159.4TFA

Properties (3)

customer
1
datetime
2021-11-17T06:00:00-08:00
is_lateral_inspection
false