Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Sep 21, 2021, 12:00 PM
  • P12985_15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5_15 0785_15 0784_POST_SI_Memo.mpg

Date
09/21/2021
W/O
Weather
Dry
Operator/Surveyor
O.QUEZADA
Sewer ID
Z00593
PipeID
P12985
Time
5:00 AM
Certificate
12345
System Owner
1
Date Cleaned
Pre-Cleaning
Jetting
Media Label
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Main Highway - Suburban/Rural
Location Code
B
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
POST
Project
ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Sewer Type
Gravity
Material
NRCP
Lining Method
Cured in Place
Shape
Circular
Height
15 in.
Upstream MH
15 0785
Downstream MH
15 0784
Dir. of Survey
Downstream
Length Surveyed
301.1 ft.
Total Length
301.1 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 0785 to 15 0784
MH: 15 0785MH: 15 0784downstream0 ft. AMH - Upstream Manhole, Survey Begins - POST VIDEO35.4 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"36.1 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"71.9 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"95.2 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"118.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"121 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"177.7 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"218.7 ft. TFA - Tap Factory Made Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"221.4 ft. TBA - Tap Break-In Active, at 01 o'clock, -, within 8 inches of joint: YES, 6"224.8 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"271.5 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6"274.1 ft. TFA - Tap Factory Made Active, at 10 o'clock, -, within 8 inches of joint: YES, 6"301.1 ft. AMH - Downstream Manhole, Survey Ends - POST VIDEO

Observations (14)

DistanceCodeObservation
118.1TFA
71.9TFA
95.2TBA
177.7TBA
274.1TFA
218.7TFA
0AMHPOST VIDEO
36.1TBA
224.8TFA
35.4TFA
121TFA
271.5TFA
301.1AMHPOST VIDEO
221.4TBA

Properties (3)

customer
1
datetime
2021-09-21T05:00:00-07:00
is_lateral_inspection
false