- Date
- 02/01/2022
- W/O
- 931491
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00520
- PipeID
- P18908
- Time
- 2:36 AM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9900
- Sewer Name
- 05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
- City
- INGLEWOOD
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- RFIR_WO_931491_TV05368_JAN2022
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 21 in.
- Upstream MH
- 05 0645
- Downstream MH
- 05 2435
- Dir. of Survey
- Downstream
- Length Surveyed
- 59.8 ft.
- Total Length
- 59.8 ft.
- Structural Index
- 3
- Structural Quick
- 413A
- Structural Rating
- 59
- O&M Index
- 2
- O&M Quick
- 2A00
- O&M Rating
- 24
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 83
Pipe schematic from manhole 05 0645 to 05 2435 Observation photos (2)

2.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

5.1 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES