Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 1, 2022, 10:45 AM
  • 05 2435_05 2434_02012022_024835.mp4

Date
02/01/2022
W/O
931491
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00520
PipeID
P07566
Time
2:45 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9900
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_931491_TV05368_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
24 in.
Width
12 in.
Upstream MH
05 2435
Downstream MH
05 2434
Dir. of Survey
Downstream
Length Surveyed
7.8 ft.
Total Length
7.8 ft.
Structural Index
2
Structural Quick
2200
Structural Rating
4
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
8
Pipe schematic from manhole 05 2435 to 05 2434
MH: 05 2435MH: 05 2434downstream0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 24352 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start3.6 ft. MGO - General Observation - STAINING5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish7 ft. MGO - General Observation - ROACHES @ MH7.8 ft. AMH - Downstream Manhole, Survey Ends - 05 2434

Observations (10)

DistanceCodeObservation
0MWL
5DAGS
7.8AMH05 2434
7MGOROACHES @ MH
3.6MGOSTAINING
0MWM
5SSS
2SSS
2DAGS
0AMH05 2435

Properties (7)

additional_info
630098013122201
custom_field_three
3/SPALLING/NO STRUCTURAL DAMAGE
custom_field_two
3
customer
1
datetime
2022-02-01T02:45:07-08:00
documentation
PROPIPE
is_lateral_inspection
false