Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2022, 09:44 AM
  • 05 0673_05 0672_01242022_022918.mp4

Date
01/24/2022
W/O
931491
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00520
PipeID
P05900
Time
1:44 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9711
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_931491_TV05368_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
05 0672
Downstream MH
05 0673
Dir. of Survey
Upstream
Length Surveyed
332.9 ft.
Total Length
332.9 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
335
O&M Index
2
O&M Quick
2D00
O&M Rating
50
Overall Index
2
Overall Quick
Overall Rating
385
Pipe schematic from manhole 05 0672 to 05 0673
MH: 05 0672MH: 05 0673upstream0 ft. AMH - Upstream Manhole, Survey Ends - 05 06732.2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish2.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish46.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8" - OPEN98.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 6" - OPEN147.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8" - OPEN199.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8" - OPEN207.8 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish249.3 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8" - OPEN290 ft. CM - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES294.3 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES300.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: YES, 8"330.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start330.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start330.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start332.9 ft. MWM - Water Mark, 20 %of cross sectional area332.9 ft. MWL - Water Level, 15 %of cross sectional area332.9 ft. AMH - Downstream Manhole, Survey Begins - 05 0672332.9 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

    38.6 ft. - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

    42.9 ft. - Crack Multiple, from 11 to 03 o'clock, within 8 inches of joint: YES

Observations (19)

DistanceCodeObservation
83.6TFOPEN
0MWM
0MWL
125.1DAGS
2SSS
330SSS
38.6CL
185.1TFOPEN
330.7CM
133.2TFOPEN
0AMH05 0672
42.9CM
2DAGS
2CM
234.7TFOPEN
286.8TFOPEN
332.9AMH05 0673
32.1TFC
0MGOCONN @ MH 3 O'CLOCK/ACTIVE

Properties (7)

additional_info
630098012422001
custom_field_three
SPALLING/MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2022-01-24T01:44:10-08:00
documentation
PRO PIPE
is_lateral_inspection
false