Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 24, 2022, 12:22 PM
  • 05 0658_05 0657_01242022_044350.mp4

Date
01/24/2022
W/O
931491
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00520
PipeID
P05883
Time
4:22 AM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9711
Sewer Name
05 SOUTH INGLEWOOD-ORANGE AVENUE TRUNK
City
INGLEWOOD
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_931491_TV05368_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
05 0658
Downstream MH
05 0657
Dir. of Survey
Downstream
Length Surveyed
352.4 ft.
Total Length
352.4 ft.
Structural Index
2
Structural Quick
3K2M
Structural Rating
327
O&M Index
2
O&M Quick
2M00
O&M Rating
140
Overall Index
2
Overall Quick
Overall Rating
467
Pipe schematic from manhole 05 0658 to 05 0657
MH: 05 0658MH: 05 0657downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 06580 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start10.5 ft. CM - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES27.7 ft. CM - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES45.6 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES48.6 ft. CS - Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES69.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 8" - OPEN116.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8" - OPEN168.7 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 8" - OPEN219.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN267.1 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 8" - OPEN317.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 8" - OPEN348.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish350 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish350 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish352.4 ft. AMH - Downstream Manhole, Survey Ends - 05 0657352.4 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (5)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

    10.5 ft. - Crack Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

    27.7 ft. - Crack Multiple, from 08 to 11 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    45.6 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES

    48.6 ft. - Crack Spiral, from 10 to 02 o'clock, within 8 inches of joint: YES

Observations (22)

DistanceCodeObservation
348.9CM
350DAGS
0AMH05 0658
27.7CM
317.9TFOPEN
0MWL
116.1TFOPEN
352.4AMH05 0657
350SSS
0MWM
267.1TFOPEN
352.4MGOCONN @ MH 3 O'CLOCK/ACTIVE
219.1TFOPEN
69.1TFOPEN
2CM
2DAGS
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
2SSS
48.6CS
10.5CM
168.7TFOPEN
45.6CL

Properties (7)

additional_info
630098012422001
custom_field_three
MULTIPLE CRACKS/SPALLING
custom_field_two
3
customer
1
datetime
2022-01-24T04:22:57-08:00
documentation
PRO PIPE
is_lateral_inspection
false