Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 7, 2022, 08:52 AM
  • 18 0472_18 0471_372022_012019.mp4

Date
03/07/2022
W/O
0931911
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00691
PipeID
P14326
Time
12:52 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3028
Sewer Name
18 NORTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Capital Improvement Program Assesment
Project
202200307MDM_NORTH_PLANT_OUTFALL_TRUNK
Material
Reinforced Concrete Pipe
Shape
Circular
Height
21 in.
Upstream MH
18 0472
Downstream MH
18 0471
Dir. of Survey
Downstream
Length Surveyed
219.9 ft.
Total Length
219.9 ft.
Structural Index
5
Structural Quick
5741
Structural Rating
41
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
41
Pipe schematic from manhole 18 0472 to 18 0471
MH: 18 0472MH: 18 0471downstream0 ft. AMH - Upstream Manhole, Survey Begins - 1:15AM0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 30 %of cross sectional area2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG5.7 ft. SRC - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR9.8 ft. SRC - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR13.8 ft. SRC - Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR15 ft. SRC - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: NO - LONG REBAR24.9 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR62.2 ft. MGO - General Observation - 40% MAG COAT72.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open117.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open125.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open183.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open192.7 ft. SRC - Surface Reinforcement Corroded, from 09 to 10 o'clock, within 8 inches of joint: NO - LONG REBAR201.7 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - MISSING LONG CIRCUM REBAR206.3 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - MISSING LONG CIRCUM REBAR219.2 ft. SRC - Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR219.2 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - SEVERE AGG219.2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR MISSING SPORATIC219.2 ft. SRC - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES, Finish - LONG CIRCUM REBAR219.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - BLISTERING PEELING CONCRETE219.9 ft. AMH - Downstream Manhole, Survey Ends - 1:45AM

Observation photos (10)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - BLISTERING PEELING CONCRETE

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

    2 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

  • Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

    5.7 ft. - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: YES, Start - LONG & CIRCUM REBAR

  • Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    9.8 ft. - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

    13.8 ft. - Surface Reinforcement Corroded, from 08 to 09 o'clock, within 8 inches of joint: YES, Start - CIRCUM REBAR

  • Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: NO - LONG REBAR

    15 ft. - Surface Reinforcement Corroded, from 03 to 04 o'clock, within 8 inches of joint: NO - LONG REBAR

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

    24.9 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - LONG CIRCUM REBAR

  • General Observation - 40% MAG COAT

    62.2 ft. - General Observation - 40% MAG COAT

  • Surface Reinforcement Corroded, from 09 to 10 o'clock, within 8 inches of joint: NO - LONG REBAR

    192.7 ft. - Surface Reinforcement Corroded, from 09 to 10 o'clock, within 8 inches of joint: NO - LONG REBAR

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - MISSING LONG CIRCUM REBAR

    201.7 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - MISSING LONG CIRCUM REBAR

Observations (24)

DistanceCodeObservation
0AMH1:15AM
219.2SRCLONG CIRCUM REBAR
183.6TFOpen
62.2MGO40% MAG COAT
206.3SRCMISSING LONG CIRCUM REBAR
0MWL
0MWM
192.7SRCLONG REBAR
219.2SAMSEVERE AGG
117.4TFOpen
15SRCLONG REBAR
24.9SRCLONG CIRCUM REBAR
219.2SRCLONG CIRCUM REBAR MISSING SPORATIC
5.7SRCLONG & CIRCUM REBAR
13.8SRCCIRCUM REBAR
9.8SRCCIRCUM REBAR
219.2SRCLONG CIRCUM REBAR
125.8TFOpen
2SSSBLISTERING PEELING CONCRETE
219.9AMH1:45AM
72.7TFOpen
2SAMSEVERE AGG
201.7SRCMISSING LONG CIRCUM REBAR
219.2SSSBLISTERING PEELING CONCRETE

Properties (6)

custom_field_three
LONG CIRCUM REBAR CORRODED MISSING
custom_field_two
1
customer
LACSD
datetime
2022-03-07T00:52:37-08:00
documentation
MARTIN,REVELES,OLIVER 111,CASTILLO
is_lateral_inspection
false