Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 7, 2022, 10:37 AM
  • 22 0275_22 0274_01072022_024517.mp4

Date
01/07/2022
W/O
931878
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16561
Time
2:37 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9758
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_931878_TV22016_JAN2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0275
Downstream MH
22 0274
Dir. of Survey
Downstream
Length Surveyed
196.8 ft.
Total Length
196.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 0275 to 22 0274
MH: 22 0275MH: 22 0274downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 02750 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 6 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. MWL - Water Level, 5 %of cross sectional area2.1 ft. MGO - General Observation - LINED PIPE196.8 ft. AMH - Downstream Manhole, Survey Ends - 22 0274196.8 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observations (8)

DistanceCodeObservation
0AMH22 0275
196.8AMH22 0274
196.8MGOCONNECTION AT MH 9 O'CLOCK
0MWM
0MGOCONNECTION AT MH 6 O'CLOCK
2.1MGOLINED PIPE
0MGOCONNECTION AT MH 9 O'CLOCK
0MWL

Properties (7)

additional_info
6300908010622201
custom_field_three
RFIR NO SEVERE DEFECTS. (LINED PIPE)
custom_field_two
3
customer
1
datetime
2022-01-07T02:37:18-08:00
documentation
PROPIPE
is_lateral_inspection
false