Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 6, 2022, 06:52 AM
  • 22 0272A_22 0272_01052022_230233.mp4

Date
01/05/2022
W/O
931878
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16558
Time
10:52 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9757
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_931878_TV22016_JAN2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0272A
Downstream MH
22 0272
Dir. of Survey
Downstream
Length Surveyed
168.3 ft.
Total Length
168.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 0272A to 22 0272
MH: 22 0272AMH: 22 0272downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 0272A2 ft. MGO - General Observation - LINED PIPE128.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"168.3 ft. AMH - Downstream Manhole, Survey Ends - 22 0272

Observations (7)

DistanceCodeObservation
0MWL
128.7TF
0MGOCONNECTION AT MH 3 O'CLOCK
0MWM
0AMH22 0272A
168.3AMH22 0272
2MGOLINED PIPE

Properties (7)

additional_info
6300908010522201
custom_field_three
RFIR NO SEVERE DEFECTS. (LINED PIPE)
custom_field_two
3
customer
1
datetime
2022-01-05T22:52:04-08:00
documentation
PROPIPE
is_lateral_inspection
false