Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 6, 2022, 05:48 AM
  • 22 0269_22 1388_01052022_215521.mp4

Date
01/05/2022
W/O
931878
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16554
Time
9:48 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9757
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_931878_TV22016_JAN2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0269
Downstream MH
22 1388
Dir. of Survey
Downstream
Length Surveyed
120.2 ft.
Total Length
120.2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 0269 to 22 1388
MH: 22 0269MH: 22 1388downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK0 ft. AMH - Upstream Manhole, Survey Begins - 22 02690 ft. MWL - Water Level, 10 %of cross sectional area3.8 ft. MGO - General Observation - LINED PIPE52.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"120.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK120.2 ft. AMH - Downstream Manhole, Survey Ends - 22 1388120.2 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observations (9)

DistanceCodeObservation
52.8TF
0MWM
0MGOCONNECTION AT MH 9 O'CLOCK
120.2MGOCONNECTION AT MH 9 O'CLOCK
0AMH22 0269
0MWL
3.8MGOLINED PIPE
120.2AMH22 1388
120.2MGOCONNECTION AT MH 3 O'CLOCK

Properties (7)

additional_info
6300908010522201
custom_field_three
RFIR NO SEVERE DEFECTS. (LINED PIPE)
custom_field_two
3
customer
1
datetime
2022-01-05T21:48:06-08:00
documentation
PROPIPE
is_lateral_inspection
false