Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 6, 2022, 11:09 AM
  • 22 0261_22 0260_01062022_032452.mp4

Date
01/06/2022
W/O
931878
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16543
Time
3:09 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9757
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_931878_TV22016_JAN2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0261
Downstream MH
22 0260
Dir. of Survey
Downstream
Length Surveyed
322.3 ft.
Total Length
322.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 0261 to 22 0260
MH: 22 0261MH: 22 0260downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 02610 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2.6 ft. MGO - General Observation - LINED PIPE45.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"242.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"322.3 ft. AMH - Downstream Manhole, Survey Ends - 22 0260322.3 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK

Observations (9)

DistanceCodeObservation
322.3AMH22 0260
0MWL
45.6TF
0MWM
322.3MGOCONNECTION AT MH 9 O'CLOCK
2.6MGOLINED PIPE
242.1TF
0AMH22 0261
0MGOCONNECTION AT MH 9 O'CLOCK

Properties (7)

additional_info
6300908010522201
custom_field_three
RFIR NO SEVERE DEFECTS. (LINED PIPE)
custom_field_two
3
customer
1
datetime
2022-01-06T03:09:18-08:00
documentation
PROPIPE
is_lateral_inspection
false