Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 7, 2022, 06:06 AM
  • 22 0256_22 0255_01062022_221942.mp4

Date
01/06/2022
W/O
931878
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16538
Time
10:06 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9758
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_931878_TV22016_JAN2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
22 0256
Downstream MH
22 0255
Dir. of Survey
Downstream
Length Surveyed
155 ft.
Total Length
155 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 0256 to 22 0255
MH: 22 0256MH: 22 0255downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 02560 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK3 ft. MGO - General Observation - LINED PIPE20.7 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"67 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"142.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"155 ft. AMH - Downstream Manhole, Survey Ends - 22 0255

Observations (9)

DistanceCodeObservation
20.7TF
67TF
0MWL
0AMH22 0256
0MWM
155AMH22 0255
0MGOCONNECTION AT MH 9 O'CLOCK
3MGOLINED PIPE
142.2TF

Properties (7)

additional_info
6300908010622201
custom_field_three
RFIR NO SEVERE DEFECTS. (LINED PIPE)
custom_field_two
3
customer
1
datetime
2022-01-06T22:06:40-08:00
documentation
PROPIPE
is_lateral_inspection
false