Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2021, 11:27 AM
  • 08 0191_08 0172_12142021_033519.mp4

Date
12/14/2021
W/O
926526
Weather
Heavy Rain
Operator/Surveyor
B.FUGATE
Sewer ID
Z00010
PipeID
P00251
Time
3:27 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9565
Sewer Name
08 GRACE STREET TRUNK, SECTS 2&3
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_926526_TV08022_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
10 in.
Upstream MH
08 0191
Downstream MH
08 0172
Dir. of Survey
Downstream
Length Surveyed
244.3 ft.
Total Length
244.3 ft.
Structural Index
4
Structural Quick
4F39
Structural Rating
159
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
159
Pipe schematic from manhole 08 0191 to 08 0172
MH: 08 0191MH: 08 0172downstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 01910 ft. MWL - Water Level, 5 %of cross sectional area33 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start74.1 ft. TB - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"77.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish77.1 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start123.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"244.3 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK244.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish244.3 ft. AMH - Downstream Manhole, Survey Ends - 08 0172

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    33 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

    74.1 ft. - Tap Break-In, at 12 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    77.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (12)

DistanceCodeObservation
77.1CM
244.3MGOCONNECTION AT THE MH 9 OC'LOCK
33CM
0MGOCONNECTION AT THE MH 9 OC'LOCK
77.1FM
0MWM
74.1TB
0AMH08 0191
123.8TF
0MWL
244.3FM
244.3AMH08 0172

Properties (7)

additional_info
630074121321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-12-14T03:27:16-08:00
documentation
PROPIPE
is_lateral_inspection
false