Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2021, 06:59 AM
  • 08 0207_08 0206_12132021_233239.mp4

Date
12/13/2021
W/O
926526
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00010
PipeID
P00267
Time
10:59 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9565
Sewer Name
08 GRACE STREET TRUNK, SECTS 2&3
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_926526_TV08022_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
08 0207
Downstream MH
08 0206
Dir. of Survey
Downstream
Length Surveyed
352.4 ft.
Total Length
352.4 ft.
Structural Index
4
Structural Quick
4M00
Structural Rating
276
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
4
Overall Quick
Overall Rating
278
Pipe schematic from manhole 08 0207 to 08 0206
MH: 08 0207MH: 08 0206downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 02070 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area5.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start10.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"29.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"68.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"102.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"107.7 ft. TBA - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"107.7 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 05 o'clock, , within 8 inches of joint: YES126 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"152.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"199.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"206.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"229.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"255.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"295.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"305.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"336.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"339.5 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"352.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish352.3 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK352.4 ft. AMH - Downstream Manhole, Survey Ends - 08 0206

Observation photos (4)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    107.7 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Deposits Attached Grease, 10 %of cross sectional area, from 03 to 05 o'clock,  , within 8 inches of joint: YES

    107.7 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 05 o'clock, , within 8 inches of joint: YES

  • Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"

    339.5 ft. - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 6"

Observations (24)

DistanceCodeObservation
107.7TBA
5.2FM
352.4AMH08 0206
339.5TB
0AMH08 0207
206.2TFC
305.7TF
102.3TFC
352.3FM
352.3MGOCONNECTION AT THE MH 3 OC'LOCK
29.6TFC
91.7TFC
255.9TFC
199.6TFC
10.6TFC
336.7TFC
229.1TFC
126TFC
107.7DAGS
152.1TF
295.1TF
0MWL
0MWM
68.5TF

Properties (7)

additional_info
630074121321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-12-13T22:59:52-08:00
documentation
PROPIPE
is_lateral_inspection
false