Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2021, 07:58 AM
  • 08 0205A_08 0205_12142021_000651.mp4

Date
12/13/2021
W/O
926526
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00010
PipeID
P00266
Time
11:58 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9565
Sewer Name
08 GRACE STREET TRUNK, SECTS 2&3
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_926526_TV08022_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
08 0205A
Downstream MH
08 0205
Dir. of Survey
Downstream
Length Surveyed
134.3 ft.
Total Length
134.3 ft.
Structural Index
4
Structural Quick
4D00
Structural Rating
104
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
104
Pipe schematic from manhole 08 0205A to 08 0205
MH: 08 0205AMH: 08 0205downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 0205A0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area4.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start5.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"29.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"40.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"134.3 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK134.3 ft. AMH - Downstream Manhole, Survey Ends - 08 0205134.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    4.3 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    29.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (12)

DistanceCodeObservation
4.3FM
0AMH08 0205A
0MGOCONNECTION AT THE MH 3 OC'LOCK
134.3MGOCONNECTION AT THE MH 3 OC'LOCK
5.8TF
134.3AMH08 0205
29.3TB
40.6TFC
0MWL
91.7TFC
134.3FM
0MWM

Properties (7)

additional_info
630074121321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-12-13T23:58:07-08:00
documentation
PROPIPE
is_lateral_inspection
false