Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2021, 09:52 AM
  • 08 0205_08 0204_12142021_020555.mp4

Date
12/14/2021
W/O
926526
Weather
Light Rain
Operator/Surveyor
B.FUGATE
Sewer ID
Z00010
PipeID
P00265
Time
1:52 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9565
Sewer Name
08 GRACE STREET TRUNK, SECTS 2&3
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_926526_TV08022_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
15 in.
Upstream MH
08 0204
Downstream MH
08 0205
Dir. of Survey
Upstream
Length Surveyed
328.1 ft.
Total Length
328.1 ft.
Structural Index
4
Structural Quick
4L00
Structural Rating
256
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
256
Pipe schematic from manhole 08 0204 to 08 0205
MH: 08 0204MH: 08 0205upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 02050 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish74.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"105.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"128.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"151.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"174.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"200.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"224.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"251 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"273.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"300.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"318.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start328.1 ft. MWL - Water Level, 5 %of cross sectional area328.1 ft. MWM - Water Mark, 15 %of cross sectional area328.1 ft. AMH - Downstream Manhole, Survey Begins - 08 0204

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (16)

DistanceCodeObservation
0MWL
9.9FM
328.1AMH08 0205
77.1TFC
328.1FM
153.8TF
0MWM
27.9TFC
0AMH08 0204
54.2TFC
176.6TFC
222.6TFC
103.8TFC
199.5TFC
253.4TFC
127.2TFC

Properties (7)

additional_info
630074121321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-12-14T01:52:30-08:00
documentation
PROPIPE
is_lateral_inspection
false