Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 13, 2021, 12:33 PM
  • 08 0201_08 0200_12132021_044818.mp4

Date
12/13/2021
W/O
926526
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00010
PipeID
P00261
Time
4:33 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9564
Sewer Name
08 GRACE STREET TRUNK, SECTS 2&3
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_926526_TV08022_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
10 in.
Upstream MH
08 0200
Downstream MH
08 0201
Dir. of Survey
Upstream
Length Surveyed
339.5 ft.
Total Length
339.5 ft.
Structural Index
4
Structural Quick
4K38
Structural Rating
256
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
256
Pipe schematic from manhole 08 0200 to 08 0201
MH: 08 0200MH: 08 0201upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 02010 ft. MGO - General Observation - CONNECTION AT THE MH 12 OC'LOCK0 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish87.4 ft. TS - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"143 ft. TS - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"198.5 ft. TS - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"237.8 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"269.5 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"287.8 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start287.8 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish320.1 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"329.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start339.5 ft. MWM - Water Mark, 20 %of cross sectional area339.5 ft. MWL - Water Level, 5 %of cross sectional area339.5 ft. AMH - Downstream Manhole, Survey Begins - 08 0200

Observation photos (3)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    10 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    51.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    70 ft. - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (15)

DistanceCodeObservation
339.5AMH08 0201
141TS
339.5MGOCONNECTION AT THE MH 12 OC'LOCK
196.5TS
0MWM
70TSC
101.7TSC
51.7FM
51.7CM
10CM
339.5FM
252.1TS
0MWL
19.4TSC
0AMH08 0200

Properties (7)

additional_info
630074121321003
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-12-13T04:33:18-08:00
documentation
PROPIPE
is_lateral_inspection
false