Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 13, 2021, 11:50 AM
  • 08 0200_08 0199_12132021_040704.mp4

Date
12/13/2021
W/O
926526
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00010
PipeID
P00260
Time
3:50 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9564
Sewer Name
08 GRACE STREET TRUNK, SECTS 2&3
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_926526_TV08022_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
10 in.
Upstream MH
08 0200
Downstream MH
08 0199
Dir. of Survey
Downstream
Length Surveyed
325.4 ft.
Total Length
325.4 ft.
Structural Index
4
Structural Quick
4J3B
Structural Rating
284
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
284
Pipe schematic from manhole 08 0200 to 08 0199
MH: 08 0200MH: 08 0199downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 02000 ft. MWL - Water Level, 10 %of cross sectional area0.2 ft. MWM - Water Mark, 25 %of cross sectional area3.1 ft. CM - Crack Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES13 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES35.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"39 ft. CM - Crack Multiple, from 02 to 04 o'clock, within 8 inches of joint: YES86.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"89.1 ft. CM - Crack Multiple, from 09 to 01 o'clock, within 8 inches of joint: YES109.1 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES127 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"145 ft. CL - Crack Longitudinal, at 03 o'clock, within 8 inches of joint: YES145 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES160 ft. CM - Crack Multiple, from 12 to 03 o'clock, within 8 inches of joint: YES160 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES170 ft. CM - Crack Multiple, from 08 to 10 o'clock, within 8 inches of joint: YES185.1 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES188.3 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"239.2 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"292 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES296.1 ft. CM - Crack Multiple, from 10 to 02 o'clock, within 8 inches of joint: YES299.9 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"307.1 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES325.4 ft. AMH - Downstream Manhole, Survey Ends - 08 0199

Observation photos (1)

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"

    127 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: YES, 6"

Observations (24)

DistanceCodeObservation
160CM
239.2TS
0.2MWM
127TB
296.1CM
185.1CL
145CL
160FL
145CL
307.1CL
39CM
86.9TFC
0AMH08 0200
188.3TSC
3.1CM
325.4AMH08 0199
109.1CL
0MWL
292CL
170CM
13CL
35.9TFC
89.1CM
299.9TSC

Properties (7)

additional_info
630074121321003
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-12-13T03:50:01-08:00
documentation
PROPIPE
is_lateral_inspection
false