Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2021, 10:38 AM
  • 08 0197_08 0196_12142021_025106.mp4

Date
12/14/2021
W/O
926526
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00010
PipeID
P00257
Time
2:38 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9565
Sewer Name
08 GRACE STREET TRUNK, SECTS 2&3
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_926526_TV08022_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
10 in.
Upstream MH
08 0197
Downstream MH
08 0196
Dir. of Survey
Downstream
Length Surveyed
344.7 ft.
Total Length
344.7 ft.
Structural Index
4
Structural Quick
4M31
Structural Rating
283
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
283
Pipe schematic from manhole 08 0197 to 08 0196
MH: 08 0197MH: 08 0196downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 08 01974.9 ft. CM - Crack Multiple, from 09 to 11 o'clock, within 8 inches of joint: YES59.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"97.1 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES111.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"157.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"212.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"227.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"265.6 ft. CL - Crack Longitudinal, at 10 o'clock, within 8 inches of joint: YES268.5 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"319.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"321.1 ft. FM - Fracture Multiple, from 10 to 03 o'clock, within 8 inches of joint: YES344.7 ft. AMH - Downstream Manhole, Survey Ends - 08 0196344.7 ft. MGO - General Observation - CONNECTION AT THE MH 12 OC'LOCK

Observations (16)

DistanceCodeObservation
111.1TF
157.6TF
4.9CM
344.7AMH08 0196
319.3TFC
344.7MGOCONNECTION AT THE MH 12 OC'LOCK
265.6CL
0MWL
212.2TFC
268.5TF
227.3TFC
0MWM
0AMH08 0197
59.6TF
321.1FM
97.1CL

Properties (7)

additional_info
630074121321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-12-14T02:38:55-08:00
documentation
PROPIPE
is_lateral_inspection
false