Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 14, 2021, 11:54 AM
  • 08 0195_08 0194_12142021_040909.mp4

Date
12/14/2021
W/O
926526
Weather
Heavy Rain
Operator/Surveyor
B.FUGATE
Sewer ID
Z00010
PipeID
P00255
Time
3:54 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9565
Sewer Name
08 GRACE STREET TRUNK, SECTS 2&3
City
CARSON
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_926526_TV08022_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
10 in.
Upstream MH
08 0194
Downstream MH
08 0195
Dir. of Survey
Upstream
Length Surveyed
419.7 ft.
Total Length
419.7 ft.
Structural Index
4
Structural Quick
4O31
Structural Rating
335
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
335
Pipe schematic from manhole 08 0194 to 08 0195
MH: 08 0194MH: 08 0195upstream0 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. AMH - Upstream Manhole, Survey Ends - 08 01950 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK7.7 ft. CC - Crack Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES48.1 ft. TSC - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"99.1 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"104.2 ft. TS - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"104.7 ft. CL - Crack Longitudinal, at 11 o'clock, within 8 inches of joint: YES160.4 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"210.1 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6", 6"215.1 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"261.6 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"317.6 ft. TS - Tap Saddle, at 10 o'clock, -, within 8 inches of joint: NO, 6"333.1 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"347.7 ft. CC - Crack Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES363 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"378.1 ft. TS - Tap Saddle, at 02 o'clock, -, within 8 inches of joint: NO, 6"407.5 ft. CM - Crack Multiple, from 10 to 04 o'clock, within 8 inches of joint: YES409.1 ft. TSC - Tap Saddle Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"419.7 ft. MWL - Water Level, 10 %of cross sectional area419.7 ft. MWM - Water Mark, 20 %of cross sectional area419.7 ft. AMH - Downstream Manhole, Survey Begins - 08 0194

Observation photos (1)

  • Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    371.6 ft. - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

Observations (22)

DistanceCodeObservation
371.6TSC
419.7MGOCONNECTION AT THE MH 9 OC'LOCK
320.6TS
41.6TS
0MWL
412CC
204.6TS
158.1TSC
72CC
86.6TS
56.7TFC
0MWM
259.3TSC
315CL
12.2CM
419.7AMH08 0195
10.6TSC
0AMH08 0194
419.7MGOCONNECTION AT THE MH 3 OC'LOCK
209.6TSC
102.1TS
315.5TS

Properties (7)

additional_info
630074121321201
custom_field_three
MULTIPLE FRACTURE'S
custom_field_two
2
customer
1
datetime
2021-12-14T03:54:49-08:00
documentation
PROPIPE
is_lateral_inspection
false