Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Mar 1, 2022, 08:39 AM
  • 18 0489_18 0488_312022_011816.mp4

Date
03/01/2022
W/O
0931911
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00691
PipeID
P14343
Time
12:39 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3005
Sewer Name
18 NORTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
14
Purpose
Capital Improvement Program Assesment
Project
20220301MDM_NORTH_OUTFALL_PLANT
Material
Vitrified Clay Pipe
Shape
Circular
Height
16 in.
Upstream MH
18 0489
Downstream MH
18 0488
Dir. of Survey
Downstream
Length Surveyed
332.4 ft.
Total Length
332.4 ft.
Structural Index
3
Structural Quick
5239
Structural Rating
75
O&M Index
2
O&M Quick
2100
O&M Rating
2
Overall Index
2
Overall Quick
Overall Rating
77
Pipe schematic from manhole 18 0489 to 18 0488
MH: 18 0489MH: 18 0488downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MGO - General Observation - Conn. @ Mh, 3 O' Clock. Active0 ft. AMH - Upstream Manhole, Survey Begins - 1:15AM2.2 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - HAIRLINE4.4 ft. FC - Fracture Circumferential, from 11 to 04 o'clock, within 8 inches of joint: YES - SLIGHT7.2 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - H7.2 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - SLIUGHT12.4 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL17.8 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - SL25.3 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES - SL26 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H27.6 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - H35.2 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H40.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - H54 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H57.1 ft. FC - Fracture Circumferential, from 09 to 11 o'clock, within 8 inches of joint: YES - H59.3 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H67.6 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL71.6 ft. TFA - Tap Factory Made Active, at 09 o'clock, -, within 8 inches of joint: YES, 6" - Active106.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL124.6 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - H127.4 ft. FC - Fracture Circumferential, from 09 to 03 o'clock, within 8 inches of joint: YES - SL135.2 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL137.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H141.2 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Active145.5 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - DEFECTIVE CORRODING VCP PIPE145.5 ft. MGP - General Photograph - DEFECTIVE VCP PIPE148.7 ft. SZ - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish - DEFECTIVE VCP177.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open218.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H224.3 ft. FC - Fracture Circumferential, from 10 to 02 o'clock, within 8 inches of joint: YES - H224.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - H227.4 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - ACTIVE241 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES, Start - H241 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL245.2 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES, Finish - H259.3 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - SL262 ft. FC - Fracture Circumferential, from 10 to 12 o'clock, within 8 inches of joint: YES - SL263.9 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - SL267.5 ft. SZ - Surface Other, from 11 to 01 o'clock, within 8 inches of joint: YES - DEFECTIVE VCP273.3 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H276.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Finish - H283.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, - H293.6 ft. MGP - General Photograph - POSSIBLE REPAIR294.2 ft. MGP - General Photograph - POSSIBLE REPAIR294.2 ft. H - Hole, from 08 to 10 o'clock, within 8 inches of joint: YES - POSSIBLE REPAIR294.2 ft. MGP - General Photograph - POSSIBLE REPAIR294.2 ft. H - Hole, from 01 to 04 o'clock, within 8 inches of joint: YES - MISSING PIPE POSSIBLE REPAIR326.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES331.3 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - SL332.4 ft. AMH - Downstream Manhole, Survey Ends - 2:15AM

Observation photos (13)

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

    26 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL

    67.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - SL

  • Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - DEFECTIVE CORRODING VCP PIPE

    145.5 ft. - Surface Other, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - DEFECTIVE CORRODING VCP PIPE

  • General Photograph - DEFECTIVE VCP PIPE

    145.5 ft. - General Photograph - DEFECTIVE VCP PIPE

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

    218.5 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

    241 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - SL

  • Surface Other, from 11 to 01 o'clock, within 8 inches of joint: YES - DEFECTIVE VCP

    267.5 ft. - Surface Other, from 11 to 01 o'clock, within 8 inches of joint: YES - DEFECTIVE VCP

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

    273.3 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start - H

  • General Photograph - POSSIBLE REPAIR

    294.2 ft. - General Photograph - POSSIBLE REPAIR

  • Hole, from 08 to 10 o'clock, within 8 inches of joint: YES - POSSIBLE REPAIR

    294.2 ft. - Hole, from 08 to 10 o'clock, within 8 inches of joint: YES - POSSIBLE REPAIR

  • General Photograph - POSSIBLE REPAIR

    294.2 ft. - General Photograph - POSSIBLE REPAIR

  • Hole, from 01 to 04 o'clock, within 8 inches of joint: YES - MISSING PIPE POSSIBLE REPAIR

    294.2 ft. - Hole, from 01 to 04 o'clock, within 8 inches of joint: YES - MISSING PIPE POSSIBLE REPAIR

  • Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock,  , within 8 inches of joint: YES

    326.1 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 09 to 03 o'clock, , within 8 inches of joint: YES

Observations (52)

DistanceCodeObservation
145.5SZDEFECTIVE CORRODING VCP PIPE
273.3FLH
267.5SZDEFECTIVE VCP
4.4FCSLIGHT
12.4FCSL
71.6TFAActive
54FCH
145.5MGPDEFECTIVE VCP PIPE
263.9FLSL
241FLH
17.8FCSL
331.3FCSL
241FLSL
326.1DAGS
294.2MGPPOSSIBLE REPAIR
218.5FLH
57.1FCH
35.2FCH
259.3FCSL
124.6FCH
332.4AMH2:15AM
67.6FLSL
148.7SZDEFECTIVE VCP
135.2FCSL
141.2TBActive
224.3FCH
40.6FLH
245.2FLH
177.6TFOpen
293.6MGPPOSSIBLE REPAIR
59.3FCH
276.5FLH
27.6FCH
127.4FCSL
26FLH
137.6FCH
283.8FLH
0MWL
2.2FCHAIRLINE
0MWM
294.2HPOSSIBLE REPAIR
106.2FLSL
262FCSL
7.2FCH
294.2MGPPOSSIBLE REPAIR
227.4TBACTIVE
7.2FLSLIUGHT
0MGOConn. @ Mh, 3 O' Clock. Active
0AMH1:15AM
25.3FCSL
224.3FLH
294.2HMISSING PIPE POSSIBLE REPAIR

Properties (6)

custom_field_three
DEFECTIVE VCP-LONG SLIGHT FRACTURES
custom_field_two
2
customer
LACSD
datetime
2022-03-01T00:39:27-08:00
documentation
MARTIN,OLIVER 111,CASTILLO
is_lateral_inspection
false