Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 23, 2021, 10:54 AM
  • 22 0291_22 0290_12232021_030023.mp4

Date
12/23/2021
W/O
931725
Weather
Light Rain
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00793
PipeID
P16577
Time
2:54 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9753
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
32
Purpose
Routine Assessment
Project
RFIR_WO_931725_TV22014_JAN2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0290
Downstream MH
22 0291
Dir. of Survey
Upstream
Length Surveyed
91.5 ft.
Total Length
91.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2B00
O&M Rating
34
Overall Index
2
Overall Quick
Overall Rating
34
Pipe schematic from manhole 22 0290 to 22 0291
MH: 22 0290MH: 22 0291upstream0 ft. AMH - Upstream Manhole, Survey Ends - 22 02912.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish89.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start89.5 ft. MGO - General Observation - LINED PIPE91.5 ft. MWL - Water Level, 10 %of cross sectional area91.5 ft. AMH - Downstream Manhole, Survey Begins - 22 029091.5 ft. MWM - Water Mark, 15 %of cross sectional area91.5 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE

Observations (8)

DistanceCodeObservation
0MWL
91.5AMH22 0291
0AMH22 0290
2DAGS
0MWM
89DAGS
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
2MGOLINED PIPE