Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 23, 2021, 10:38 AM
  • 22 0290_22 0289_12232021_025314.mp4

Date
12/23/2021
W/O
931725
Weather
Light Rain
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00793
PipeID
P16576
Time
2:38 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9753
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_931725_TV22014_JAN2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0289
Downstream MH
22 0290
Dir. of Survey
Upstream
Length Surveyed
275.3 ft.
Total Length
275.3 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2J00
O&M Rating
108
Overall Index
2
Overall Quick
Overall Rating
108
Pipe schematic from manhole 22 0289 to 22 0290
MH: 22 0289MH: 22 0290upstream0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Ends - 22 02902.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish53.1 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN68.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN158.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN162.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN200 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN219.2 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN269.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN273.3 ft. MGO - General Observation - LINED PIPE273.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start275.3 ft. AMH - Downstream Manhole, Survey Begins - 22 0289275.3 ft. MWL - Water Level, 10 %of cross sectional area275.3 ft. MWM - Water Mark, 15 %of cross sectional area

Observations (15)

DistanceCodeObservation
275.3MGOCONN @ MH 9 O'CLOCK/ACTIVE
2MGOLINED PIPE
56.1TFOPEN
5.5TFOPEN
222.2TFOPEN
275.3AMH22 0290
273DAGS
75.3TFOPEN
0AMH22 0289
112.9TFOPEN
2DAGS
0MWL
116.9TFOPEN
0MWM
206.5TFOPEN

Properties (7)

additional_info
630098122221201
custom_field_three
LINED PIPE
custom_field_two
4
customer
1
datetime
2021-12-23T02:38:36-08:00
documentation
PROPIPE
is_lateral_inspection
false