Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 23, 2021, 11:15 AM
  • 22 0289_22 0288_12232021_032749.mp4

Date
12/23/2021
W/O
931725
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00793
PipeID
P16575
Time
3:15 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9753
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
COVINA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
31
Purpose
Routine Assessment
Project
RFIR_WO_931725_TV22014_JAN2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0289
Downstream MH
22 0288
Dir. of Survey
Downstream
Length Surveyed
266.5 ft.
Total Length
266.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
2I00
O&M Rating
104
Overall Index
2
Overall Quick
Overall Rating
104
Pipe schematic from manhole 22 0289 to 22 0288
MH: 22 0289MH: 22 0288downstream0 ft. MWM - Water Mark, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 02890 ft. MWL - Water Level, 10 %of cross sectional area1.9 ft. MGO - General Observation - LINED PIPE2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start8.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN65.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN89.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN115.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN162.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN195.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN228.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 4" - OPEN245.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 4" - OPEN264 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish266.5 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/CAPPED266.5 ft. AMH - Downstream Manhole, Survey Ends - 22 0288

Observations (16)

DistanceCodeObservation
0MWM
195.6TFOPEN
162.9TFOPEN
115.3TFOPEN
2DAGS
266.5MGOCONN @ MH 3 O'CLOCK/CAPPED
8.4TFOPEN
0AMH22 0289
65.9TFOPEN
89.8TFOPEN
264DAGS
245.7TFOPEN
0MWL
1.9MGOLINED PIPE
266.5AMH22 0288
228.4TFOPEN

Properties (7)

additional_info
630098122221201
custom_field_three
LINED PIPE
custom_field_two
4
customer
1
datetime
2021-12-23T03:15:30-08:00
documentation
PROPIPE
is_lateral_inspection
false