- Date
- 11/01/2021
- W/O
- 916367
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00183
- PipeID
- P21384
- Time
- 1:53 AM
- Certificate
- U-0720-70309212
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9478
- Sewer Name
- H JOINT OUTFALL H - UNIT 7B
- City
- CITY OF INDUSTRY
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 15
- Page No.
- 38
- Purpose
- Routine Assessment
- Project
- RFIR_WO_916367_TV15231_OCT2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 39 in.
- Width
- 39 in.
- Upstream MH
- H 0630
- Downstream MH
- H 0629
- Dir. of Survey
- Downstream
- Length Surveyed
- 387.2 ft.
- Total Length
- 387.2 ft.
- Structural Index
- 3
- Structural Quick
- 3G2G
- Structural Rating
- 195
- O&M Index
- 2
- O&M Quick
- 2N1C
- O&M Rating
- 170
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 365
Pipe schematic from manhole H 0630 to H 0629 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

2 ft. - General Observation - MAG COATING THROUGHOUT

190.5 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

190.6 ft. - Surface Aggregate Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

387.2 ft. - General Observation - COCKROACHES IN MANHOLE