Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 3, 2021, 04:34 PM
  • H 0509_H 0508_11032021_090452.mp4

Date
11/03/2021
W/O
916367
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00183
PipeID
P10935
Time
9:34 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K9270
Sewer Name
H JOINT OUTFALL H - UNIT 7B
City
LA PUENTE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
34
Purpose
Routine Assessment
Project
RFIR_WO_916367_TV15231_OCT2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
45 in.
Width
45 in.
Upstream MH
H 0509
Downstream MH
H 0508
Dir. of Survey
Downstream
Length Surveyed
476.6 ft.
Total Length
476.6 ft.
Structural Index
3
Structural Quick
3R2R
Structural Rating
475
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
475
Pipe schematic from manhole H 0509 to H 0508
MH: H 0509MH: H 0508downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 05090 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MGO - General Observation - MH ABANDONED0 ft. MWL - Water Level, 25 %of cross sectional area2.1 ft. MGO - General Observation - MAG COATING3.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.8 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start53.9 ft. TB - Tap Break-In, at 01 o'clock, -, within 8 inches of joint: NO, 4"245.9 ft. TBA - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 4"476.6 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK476.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish476.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish476.6 ft. AMH - Downstream Manhole, Survey Ends - H 0508

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.8 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
3.8SAV
0AMHH 0509
0MWM
476.6MGOCONNECTION AT MH 3 O'CLOCK
476.6SSS
476.6SAV
2.1MGOMAG COATING
245.9TBA
0MGOMH ABANDONED
476.6AMHH 0508
3.8SSS
53.9TB
0MWL

Properties (7)

additional_info
630074110321061
custom_field_three
SPALLING, AGGREGATE VISIBLE
custom_field_two
2
customer
1
datetime
2021-11-03T09:34:31-07:00
documentation
PRO PIPE
is_lateral_inspection
false