- Date
- 11/23/2021
- W/O
- 921521
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00471
- PipeID
- P06990
- Time
- 1:54 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9547
- Sewer Name
- 05 LOMITA TRUNK
- City
- HARBOR CITY
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 32
- Purpose
- Routine Assessment
- Project
- RFIR_WO_921521_TV05198_NOV2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 18 in.
- Upstream MH
- 05 1762
- Downstream MH
- 05 1763
- Dir. of Survey
- Upstream
- Length Surveyed
- 105.5 ft.
- Total Length
- 105.5 ft.
- Structural Index
- 2
- Structural Quick
- 2C00
- Structural Rating
- 42
- O&M Index
- 3
- O&M Quick
- 4224
- O&M Rating
- 16
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 58
Pipe schematic from manhole 05 1762 to 05 1763 Observation photos (2)

2 ft. - Deposits Attached Grease, 10 %of cross sectional area, from 02 to 10 o'clock, , within 8 inches of joint: YES, Start

2.3 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start