- Date
- 11/22/2021
- W/O
- 921521
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00471
- PipeID
- P06983
- Time
- 9:24 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9547
- Sewer Name
- 05 LOMITA TRUNK
- City
- HARBOR CITY
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 28
- Purpose
- Routine Assessment
- Project
- RFIR_WO_921521_TV05198_NOV2021
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 18 in.
- Upstream MH
- 05 1756
- Downstream MH
- 05 1755
- Dir. of Survey
- Downstream
- Length Surveyed
- 429.6 ft.
- Total Length
- 429.6 ft.
- Structural Index
- 2
- Structural Quick
- 3I2P
- Structural Rating
- 317
- O&M Index
- 2
- O&M Quick
- 2a00
- O&M Rating
- 340
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 657
Pipe schematic from manhole 05 1756 to 05 1755 Observation photos (4)

2.1 ft. - Deposits Settled Other, 10 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES, Start

42.2 ft. - Tap Saddle Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"

71.6 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start

178.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES, Start