Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 24, 2021, 07:21 AM
  • 05 1701_05 1700_11232021_233810.mp4

Date
11/23/2021
W/O
921521
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00471
PipeID
P06927
Time
11:21 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9548
Sewer Name
05 LOMITA TRUNK
City
HARBOR CITY
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
36
Purpose
Routine Assessment
Project
RFIR_WO_921521_TV05198_NOV2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
10 in.
Upstream MH
05 1701
Downstream MH
05 1700
Dir. of Survey
Downstream
Length Surveyed
375.7 ft.
Total Length
375.7 ft.
Structural Index
3
Structural Quick
514N
Structural Rating
449
O&M Index
2
O&M Quick
2N00
O&M Rating
148
Overall Index
3
Overall Quick
Overall Rating
597
Pipe schematic from manhole 05 1701 to 05 1700
MH: 05 1701MH: 05 1700downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 17010 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 25 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start3.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start279 ft. B - Broken, from 07 to 10 o'clock, within 8 inches of joint: YES373 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish373 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish375.7 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish375.7 ft. AMH - Downstream Manhole, Survey Ends - 05 1700

Observation photos (1)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
0AMH05 1701
0MWM
373DAGS
3.2FM
2DAGS
375.7FM
0MWL
2SSS
375.7AMH05 1700
373SSS
279B

Properties (7)

additional_info
630074112321201
custom_field_three
MULTIPLE FRACTURES THROUGHOUT
custom_field_two
2
customer
1
datetime
2021-11-23T23:21:01-08:00
documentation
PROPIPE
is_lateral_inspection
false