Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 22, 2021, 10:54 AM
  • 01 0185A_01 0185_12222021_025801.mp4

Date
12/22/2021
W/O
926628
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00202
PipeID
P01227
Time
2:54 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9646
Sewer Name
01 COMPTON AVENUE TRUNK
City
LOS ANGELES
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_926628_TV01237_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
01 0185A
Downstream MH
01 0185
Dir. of Survey
Downstream
Length Surveyed
18.1 ft.
Total Length
18.1 ft.
Structural Index
4
Structural Quick
4100
Structural Rating
4
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
4
Pipe schematic from manhole 01 0185A to 01 0185
MH: 01 0185AMH: 01 0185downstream0 ft. MWL - Water Level, 5 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 0185A0 ft. MWM - Water Mark, 10 %of cross sectional area2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start16.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish18.1 ft. AMH - Downstream Manhole, Survey Ends - 01 018518.1 ft. MGO - General Observation - COCKROACHES IN MH18.1 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK

Observation photos (2)

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    18.1 ft. - General Observation - COCKROACHES IN MH

Observations (8)

DistanceCodeObservation
18.1AMH01 0185
18.1MGOCOCKROACHES IN MH
0MWL
16.2FM
0AMH01 0185A
0MWM
18.1MGOCONNECTION AT MH 3 O'CLOCK
2FM

Properties (7)

additional_info
630138122121201
custom_field_three
MULTPLE FRACTURES
custom_field_two
2
customer
1
datetime
2021-12-22T02:54:10-08:00
documentation
PRO PIPE
is_lateral_inspection
false