Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Nov 23, 2021, 06:04 AM
  • B 0560_B 0559_11222021_221903.mp4

Date
11/22/2021
W/O
922056
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00101
PipeID
P09107
Time
10:04 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9284
Sewer Name
B JOINT OUTFALL B - UNIT 7
City
ROSEMEAD
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
27
Purpose
Routine Assessment
Project
WO_922056_TV15120_NOV2021
Sewer Type
Gravity
Material
CIP
Shape
Circular
Height
12 in.
Width
18 in.
Upstream MH
B 0560
Downstream MH
B 0559
Dir. of Survey
Downstream
Length Surveyed
168 ft.
Total Length
168 ft.
Structural Index
2
Structural Quick
3F2F
Structural Rating
169
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
172
Pipe schematic from manhole B 0560 to B 0559
MH: B 0560MH: B 0559downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 05600 ft. MWL - Water Level, 10 %of cross sectional area1.2 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start3.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start25.2 ft. MGP - General Photograph - CORROSION BUILD UP56.3 ft. MGP - General Photograph - SPALLING159.5 ft. MWLS - Water Level, Sag in pipe, 20 %of cross sectional area, Start168 ft. MSA - Survey Abandoned - BLOCKAGE168 ft. DSC - Deposits Settled Compacted, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - UNDER FLOW168 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish168 ft. MWLS - Water Level, Sag in pipe, 20 %of cross sectional area, Finish168 ft. SCP - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Finish

Observation photos (6)

  • Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

    1.2 ft. - Surface Corrosion Metal Pipe, from 07 to 05 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Photograph - CORROSION BUILD UP

    25.2 ft. - General Photograph - CORROSION BUILD UP

  • General Photograph - SPALLING

    56.3 ft. - General Photograph - SPALLING

  • Water Level, Sag in pipe, 20 %of cross sectional area, Start

    159.5 ft. - Water Level, Sag in pipe, 20 %of cross sectional area, Start

  • Deposits Settled Compacted,  20 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: NO - UNDER FLOW

    168 ft. - Deposits Settled Compacted, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: NO - UNDER FLOW

Observations (13)

DistanceCodeObservation
168MSABLOCKAGE
56.3MGPSPALLING
0MWM
168DSCUNDER FLOW
168SSS
25.2MGPCORROSION BUILD UP
168MWLS
159.5MWLS
3.7SSS
0AMHB 0560
0MWL
168SCP
1.2SCP

Properties (7)

additional_info
630069112221201
custom_field_three
MSA DUE TO BLOCKAGE
custom_field_two
2
customer
1
datetime
2021-11-22T22:04:44-08:00
documentation
PRO PIPE
is_lateral_inspection
false