Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 25, 2022, 08:00 AM
  • 01 0357_01 0356_01252022_001831.mp4

Date
01/25/2022
W/O
931732
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00215
PipeID
P00831
Time
12:00 AM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9850
Sewer Name
01 NADEAU TRUNK, SECTS 2&1
City
FLORENCE-GRAHAM
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_931732_TV01077_JAN2022
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Square
Height
15 in.
Width
18 in.
Upstream MH
01 0357
Downstream MH
01 0356
Dir. of Survey
Downstream
Length Surveyed
338.2 ft.
Total Length
338.2 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
4121
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 01 0357 to 01 0356
MH: 01 0357MH: 01 0356downstream0 ft. MGO - General Observation - COCKROACHES IN MH0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 01 03570 ft. MWM - Water Mark, 50 %of cross sectional area2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start30.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start336.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish336.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish338.2 ft. MGO - General Observation - COCKROACHES IN MH338.2 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK338.2 ft. AMH - Downstream Manhole, Survey Ends - 01 0356

Observation photos (4)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    30.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • General Observation - COCKROACHES IN MH

    338.2 ft. - General Observation - COCKROACHES IN MH

Observations (11)

DistanceCodeObservation
338.2MGOCOCKROACHES IN MH
336.4DAGS
0MGOCOCKROACHES IN MH
0MWL
30.1CM
2DAGS
338.2MGOCONNECTION AT MH 9 O'CLOCK
0AMH01 0357
338.2AMH01 0356
0MWM
336.4CM

Properties (7)

additional_info
630138012422202
custom_field_three
CRACKS
custom_field_two
3
customer
1
datetime
2022-01-25T00:00:34-08:00
documentation
PRO PIPE
is_lateral_inspection
false