Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 13, 2022, 10:40 AM
  • 08 0400_08 0390_01132022_025657.mp4

Date
01/13/2022
W/O
926768
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00002
PipeID
P00453
Time
2:40 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9578
Sewer Name
08 DAVIDSON CITY TRUNK, SECTION 4
City
COMPTON
Loc. details
Sidewalk
Location Code
F
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
09
Purpose
Routine Assessment
Project
WO_926768_TV08168_DEC2021
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
18 in.
Upstream MH
08 0390
Downstream MH
08 0400
Dir. of Survey
Upstream
Length Surveyed
348.2 ft.
Total Length
348.2 ft.
Structural Index
4
Structural Quick
4531
Structural Rating
25
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
25
Pipe schematic from manhole 08 0390 to 08 0400
MH: 08 0390MH: 08 0400upstream0 ft. AMH - Upstream Manhole, Survey Ends - 08 040075.6 ft. FM - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES, Finish98.2 ft. FM - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES, Start121.4 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES147.4 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"252.5 ft. CM - Crack Multiple, from 08 to 05 o'clock, within 8 inches of joint: YES329.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"348.2 ft. MWM - Water Mark, 15 %of cross sectional area348.2 ft. MGO - General Observation - ACTIVE CONNECTION AT THE MH 9 O'CLOCK348.2 ft. MWL - Water Level, 5 %of cross sectional area348.2 ft. AMH - Downstream Manhole, Survey Begins - 08 0390

Observation photos (3)

  • Crack Multiple, from 08 to 05 o'clock, within 8 inches of joint: YES

    95.7 ft. - Crack Multiple, from 08 to 05 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    226.8 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES, Start

    250 ft. - Fracture Multiple, from 11 to 02 o'clock, within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
0MWM
226.8CL
95.7CM
18.8TFC
0MGOACTIVE CONNECTION AT THE MH 9 O'CLOCK
348.2AMH08 0400
0MWL
0AMH08 0390
250FM
200.8TF
272.6FM

Properties (7)

additional_info
630074011222202
custom_field_three
FRACTURE
custom_field_two
3
customer
1
datetime
2022-01-13T02:40:14-08:00
documentation
PROPIPE
is_lateral_inspection
false