Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 23, 2021, 10:42 AM
  • 05 0138_05 2166_12232021_025338.mp4

Date
12/23/2021
W/O
926779
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00431
PipeID
P05430
Time
2:42 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9569
Sewer Name
05 DISTRICT #5 MAIN TRUNK
City
HAWTHRONE
Loc. details
Alley
Location Code
H
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
13
Purpose
Routine Assessment
Project
RFIR_WO_926779_TV05373_DEC2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
42 in.
Upstream MH
05 0138
Downstream MH
05 2166
Dir. of Survey
Downstream
Length Surveyed
161.1 ft.
Total Length
161.1 ft.
Structural Index
3
Structural Quick
513E
Structural Rating
101
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
101
Pipe schematic from manhole 05 0138 to 05 2166
MH: 05 0138MH: 05 2166downstream0 ft. MGO - General Observation - ACTIVE CONNECTION AT THE MH 6 O'CLOCK0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 01382.3 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.3 ft. MGO - General Observation - MAG COAT154 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR, PROJECTING DOWNWARD.161.1 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK161.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish161.1 ft. MGO - General Observation - STOP LOG (D/S MH) @ 8 TO 4 O'CLOCK - APPARENTLY DAMAGED: DIAGNONAL SEPERATION NEAR IT'S TOP.161.1 ft. AMH - Downstream Manhole, Survey Ends - 05 2166161.1 ft. MGO - General Observation - CONNECTION / LINE AT THE MH 12 O'CLOCK.

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR, PROJECTING DOWNWARD.

    154 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR, PROJECTING DOWNWARD.

Observations (12)

DistanceCodeObservation
161.1MGOCONNECTION AT THE MH 9 OC'LOCK
154SRCBROKEN REBAR, PROJECTING DOWNWARD.
0MGOACTIVE CONNECTION AT THE MH 6 O'CLOCK
161.1SAP
2.3SAP
0MWM
161.1MGOSTOP LOG (D/S MH) @ 8 TO 4 O'CLOCK - APPARENTLY DAMAGED: DIAGNONAL SEPERATION NEAR IT'S TOP.
161.1AMH05 2166
161.1MGOCONNECTION / LINE AT THE MH 12 O'CLOCK.
2.3MGOMAG COAT
0MWL
0AMH05 0138

Properties (7)

additional_info
630074122221201
custom_field_three
AGGREGATE PROJECTING/REINFORCEMENT VISIBLE-BROKEN
custom_field_two
1
customer
1
datetime
2021-12-23T02:42:25-08:00
documentation
PROPIPE
is_lateral_inspection
false