- Date
- 12/23/2021
- W/O
- 926779
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00431
- PipeID
- P05430
- Time
- 2:42 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9569
- Sewer Name
- 05 DISTRICT #5 MAIN TRUNK
- City
- HAWTHRONE
- Loc. details
- Alley
- Location Code
- H
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- RFIR_WO_926779_TV05373_DEC2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 33 in.
- Width
- 42 in.
- Upstream MH
- 05 0138
- Downstream MH
- 05 2166
- Dir. of Survey
- Downstream
- Length Surveyed
- 161.1 ft.
- Total Length
- 161.1 ft.
- Structural Index
- 3
- Structural Quick
- 513E
- Structural Rating
- 101
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 101
Pipe schematic from manhole 05 0138 to 05 2166 Observation photos (2)

2.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

154 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - BROKEN REBAR, PROJECTING DOWNWARD.