Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Feb 14, 2022, 11:35 AM
  • A 0748_A 0747_2142022_033633.mp4

Date
02/14/2022
W/O
0931750
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00314
PipeID
P07652
Time
3:35 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H3014
Sewer Name
A JOA-1A CHINO BASIN WASTEWATER LINE
City
POMONA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 21
Page No.
21
Purpose
Capital Improvement Program Assesment
Project
20220214MDM_JOA_1A_CHINO_BASIN_WASTEWATER_LINE
Material
Reinforced Concrete Pipe
Shape
Circular
Height
36 in.
Upstream MH
A 0748
Downstream MH
A 0747
Dir. of Survey
Downstream
Length Surveyed
20.7 ft.
Total Length
20.7 ft.
Structural Index
4
Structural Quick
5242
Structural Rating
20
O&M Index
5
O&M Quick
5100
O&M Rating
5
Overall Index
4
Overall Quick
Overall Rating
25
Pipe schematic from manhole A 0748 to A 0747
MH: A 0748MH: A 0747downstream0 ft. MWL - Water Level, 60 %of cross sectional area0 ft. MWM - Water Mark, 80 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 3:50AM1 ft. MGO - General Observation - AIR VENT2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - BLISTERING PEELING CONCRETE8.1 ft. SRV - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR10.1 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG13 ft. MGO - General Observation - UNUSAL AREA SOIL LOOK AT 8:0013.4 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - LONG CIRCUM REBAR CORRODED MISSING13.4 ft. MGO - General Observation - ZOOM APPOX 4'14.9 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO - SEVERE AGG17.4 ft. SAM - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish - SEVERE AGG17.4 ft. MGO - General Observation - ZOOM 3' APPOX17.4 ft. SRC - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - LONG CIRCUM REBAR CORRODED MISSING20.4 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish - BLISTERING PEELING CONCRETE20.7 ft. MSA - Survey Abandoned - VEIW DOWNLEG UPSTREAM SIPHON

Observation photos (9)

  • General Observation - AIR VENT

    1 ft. - General Observation - AIR VENT

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - BLISTERING PEELING CONCRETE

    2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - BLISTERING PEELING CONCRETE

  • Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

    8.1 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO - CIRCUM REBAR

  • Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

    10.1 ft. - Surface Aggregate Missing, from 08 to 04 o'clock, within 8 inches of joint: NO, Start - SEVERE AGG

  • General Observation - UNUSAL AREA SOIL LOOK AT 8:00

    13 ft. - General Observation - UNUSAL AREA SOIL LOOK AT 8:00

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - LONG CIRCUM REBAR CORRODED MISSING

    13.4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - LONG CIRCUM REBAR CORRODED MISSING

  • Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - LONG CIRCUM REBAR CORRODED MISSING

    17.4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - LONG CIRCUM REBAR CORRODED MISSING

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish - BLISTERING PEELING CONCRETE

    20.4 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish - BLISTERING PEELING CONCRETE

  • Survey Abandoned - VEIW DOWNLEG UPSTREAM SIPHON

    20.7 ft. - Survey Abandoned - VEIW DOWNLEG UPSTREAM SIPHON

Observations (16)

DistanceCodeObservation
13.4SRCLONG CIRCUM REBAR CORRODED MISSING
17.4SAMSEVERE AGG
17.4MGOZOOM 3' APPOX
8.1SRVCIRCUM REBAR
0MWL
2SSSBLISTERING PEELING CONCRETE
17.4SRCLONG CIRCUM REBAR CORRODED MISSING
10.1SAMSEVERE AGG
13MGOUNUSAL AREA SOIL LOOK AT 8:00
20.4SSSBLISTERING PEELING CONCRETE
14.9SAMSEVERE AGG
1MGOAIR VENT
13.4MGOZOOM APPOX 4'
0MWM
20.7MSAVEIW DOWNLEG UPSTREAM SIPHON
0AMH3:50AM

Properties (7)

additional_info
DOWNLEG UPSTREAM SIPHON
custom_field_three
LONG CIRCUM REBAR CORRODED MISSING
custom_field_two
1
customer
LACSD
datetime
2022-02-14T03:35:07-08:00
documentation
MARTIN,REVELES,OLIVER 111
is_lateral_inspection
false