Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 14, 2022, 08:22 AM
  • H 1289_H 1288_01142022_004011.mp4

Date
01/14/2022
W/O
931721
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01183
PipeID
P17305
Time
12:22 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9579
Sewer Name
H JOINT OUTFALL H - UNIT 8L
City
AZUSA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
12
Purpose
Routine Assessment
Project
RFIR_WO_931721_TV22154_JAN2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
H 1288
Downstream MH
H 1289
Dir. of Survey
Upstream
Length Surveyed
311.6 ft.
Total Length
311.6 ft.
Structural Index
3
Structural Quick
523K
Structural Rating
318
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
318
Pipe schematic from manhole H 1288 to H 1289
MH: H 1288MH: H 1289upstream0 ft. AMH - Upstream Manhole, Survey Ends - H 12890 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.8 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish63.4 ft. SRV - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO225 ft. SRV - Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: YES306.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start308.7 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start308.7 ft. MGO - General Observation - MAG COAT311.6 ft. AMH - Downstream Manhole, Survey Begins - H 1288311.6 ft. MWM - Water Mark, 25 %of cross sectional area311.6 ft. MWL - Water Level, 15 %of cross sectional area

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.9 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: YES

    86.6 ft. - Surface Reinforcement Visible, from 09 to 11 o'clock, within 8 inches of joint: YES

  • Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

    248.2 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO

Observations (12)

DistanceCodeObservation
0AMHH 1288
310.8SAV
2.9SAV
86.6SRV
0MWM
311.6AMHH 1289
0MWL
5.5SSS
2.9MGOMAG COAT
311.6MGOCONNECTION AT THE MH 9 OC'LOCK
248.2SRV
310.9SSS

Properties (7)

additional_info
630074011322201
custom_field_three
AGGREGATE & REBAR VISIBLE/SPALLING
custom_field_two
2
customer
1
datetime
2022-01-14T00:22:31-08:00
documentation
PROPIPE
is_lateral_inspection
false