Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 14, 2022, 07:47 AM
  • H 1286_H 1285_01142022_000019.mp4

Date
01/13/2022
W/O
931721
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z01183
PipeID
P17302
Time
11:47 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9579
Sewer Name
H JOINT OUTFALL H - UNIT 8L
City
AZUSA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_931721_TV22154_JAN2022
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
H 1286
Downstream MH
H 1285
Dir. of Survey
Downstream
Length Surveyed
328.1 ft.
Total Length
328.1 ft.
Structural Index
3
Structural Quick
523L
Structural Rating
331
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
331
Pipe schematic from manhole H 1286 to H 1285
MH: H 1286MH: H 1285downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - H 12862.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.2 ft. MGO - General Observation - MAG COAT9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start57.4 ft. SRV - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO75.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"84.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"87.6 ft. SRV - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO155.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"163.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"219.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"227.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"280.2 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"288.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"324.9 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish324.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish328 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK328.1 ft. AMH - Downstream Manhole, Survey Ends - H 1285

Observation photos (4)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO

    57.4 ft. - Surface Reinforcement Visible, at 11 o'clock, within 8 inches of joint: NO

  • Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

    87.6 ft. - Surface Reinforcement Visible, at 01 o'clock, within 8 inches of joint: NO

Observations (21)

DistanceCodeObservation
155.9TFC
219.9TFC
75.4TFC
328MGOCONNECTION AT THE MH 3 OC'LOCK
2.2SAV
87.6SRV
288.3TF
280.2TF
328.1AMHH 1285
324.9SSS
2.2MGOMAG COAT
9SSS
0MWL
163.7TFC
0MGOCONNECTION AT THE MH 3 OC'LOCK
0MWM
57.4SRV
324.9SAV
227.9TFC
84.1TFC
0AMHH 1286

Properties (7)

additional_info
630074011322201
custom_field_three
AGGREGATE, REBAR VISIBLE/SPALLING
custom_field_two
2
customer
1
datetime
2022-01-13T23:47:43-08:00
documentation
PROPIPE
is_lateral_inspection
false