Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2022, 06:13 AM
  • H 1283_H 1282_01272022_223146.mp4

Date
01/27/2022
W/O
931721
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z01183
PipeID
P17299
Time
10:13 PM
Certificate
U-115-06022794
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9717
Sewer Name
H JOINT OUTFALL H - UNIT 8L
City
AZUSA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
11
Purpose
Routine Assessment
Project
RFIR_WO_931721_TV22154_JAN2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
H 1282
Downstream MH
H 1283
Dir. of Survey
Upstream
Length Surveyed
352.4 ft.
Total Length
352.4 ft.
Structural Index
3
Structural Quick
413M
Structural Rating
214
O&M Index
3
O&M Quick
3200
O&M Rating
6
Overall Index
3
Overall Quick
Overall Rating
220
Pipe schematic from manhole H 1282 to H 1283
MH: H 1282MH: H 1283upstream0 ft. AMH - Upstream Manhole, Survey Ends - H 12830.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish80.2 ft. TBI - Tap Break-In Intruding, at 02 o'clock, -, #v, within 8 inches of joint: YES, 6", 2"134.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"184 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"243.7 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"288.7 ft. TBD - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 12", 6"316.1 ft. FM - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES335.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: YES, 6"350.4 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start352.4 ft. MWM - Water Mark, 40 %of cross sectional area352.4 ft. AMH - Downstream Manhole, Survey Begins - H 1282352.4 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (6)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

    36.3 ft. - Fracture Multiple, from 10 to 01 o'clock, within 8 inches of joint: YES

  • Tap Break-In Defective, at 02 o'clock, -,  , within 8 inches of joint: NO, 12", 6"

    63.7 ft. - Tap Break-In Defective, at 02 o'clock, -, , within 8 inches of joint: NO, 12", 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    108.7 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

    217.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Intruding, at 02 o'clock, -, #v, within 8 inches of joint: YES, 6", 2"

    272.2 ft. - Tap Break-In Intruding, at 02 o'clock, -, #v, within 8 inches of joint: YES, 6", 2"

Observations (13)

DistanceCodeObservation
0MWM
16.6TF
272.2TBI
0AMHH 1282
352.2SAP
0MWL
2SAP
36.3FM
217.7TB
168.4TF
108.7TB
352.4AMHH 1283
63.7TBD

Properties (7)

additional_info
630074012722061
custom_field_three
AGGREGATE PROJECTING
custom_field_two
2
customer
1
datetime
2022-01-27T22:13:33-08:00
documentation
PROPIPE
is_lateral_inspection
false