Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 12, 2022, 08:45 AM
  • 22 0234_22 0320_01122022_005750.mp4

Date
01/12/2022
W/O
931717
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00793
PipeID
P16516
Time
12:45 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9766
Sewer Name
22 CAMERON TRUNK, SECTS 1,2,&3
City
WEST COVINA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
35
Purpose
Routine Assessment
Project
RFIR_WO_931717_TV22160_JAN2022
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
22 0234
Downstream MH
22 0320
Dir. of Survey
Downstream
Length Surveyed
399.8 ft.
Total Length
399.8 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 22 0234 to 22 0320
MH: 22 0234MH: 22 0320downstream0 ft. AMH - Upstream Manhole, Survey Begins - 22 02340 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2 ft. MGO - General Observation - LINED PIPE34 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"82.7 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"180.1 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"229 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"328.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"399.8 ft. MGO - General Observation - CONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK399.8 ft. AMH - Downstream Manhole, Survey Ends - 22 0320

Observations (11)

DistanceCodeObservation
399.8MGOCONNECTIONS IN MH AT BOTH 3 AND 9 O' CLOCK
0AMH22 0234
328.9TF
399.8AMH22 0320
0MWM
2MGOLINED PIPE
229TF
34TF
0MWL
82.7TF
180.1TF

Properties (7)

additional_info
630098011122203
custom_field_three
RFIR NO SEVERE DEFECTS. (LINED PIPE)
custom_field_two
4
customer
1
datetime
2022-01-12T00:45:00-08:00
documentation
PROPIPE
is_lateral_inspection
false