- Date
- 12/20/2021
- W/O
- 926597
- Weather
- Dry
- Operator/Surveyor
- M.MARTINEZ
- Sewer ID
- Z00316
- PipeID
- P07841
- Time
- 11:30 AM
- Certificate
- U-115-06022794
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K9701
- Sewer Name
- A JOA-1A DISTRICT 21 INTERCEPTOR
- City
- CITY OF INDUSTRY
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 21
- Page No.
- 34
- Purpose
- Routine Assessment
- Project
- RFIR_WO_926597_TV21041_DEC2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 45 in.
- Width
- 54 in.
- Upstream MH
- A 0636
- Downstream MH
- A 0635
- Dir. of Survey
- Downstream
- Length Surveyed
- 701.8 ft.
- Total Length
- 701.8 ft.
- Structural Index
- 3
- Structural Quick
- 3[2[
- Structural Rating
- 697
- O&M Index
- 2
- O&M Quick
- 2[00
- O&M Rating
- 280
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 977
Pipe schematic from manhole A 0636 to A 0635 Observation photos (6)

2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2 ft. - General Observation - 30% MAG COAT

163.5 ft. - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: NO, 8" - OPEN

253.3 ft. - Tap Break-In Active, at 02 o'clock, -, within 8 inches of joint: NO, 12"

288.8 ft. - Tap Break-In Active, at 10 o'clock, -, within 8 inches of joint: NO, 8"

642.2 ft. - Alignment Left, 20 %