Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 26, 2022, 04:31 PM
  • B 0013_B 0012_01262022_090645.mp4

Date
01/26/2022
W/O
926981
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00072
PipeID
P08523
Time
8:31 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9585
Sewer Name
B JOINT OUTFALL B - UNIT 1A
City
CARSON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_926981_TV08132_DEC2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
144 in.
Width
33 in.
Upstream MH
B 0013
Downstream MH
B 0012
Dir. of Survey
Downstream
Length Surveyed
1039.9 ft.
Total Length
1039.9 ft.
Structural Index
3
Structural Quick
5E3i
Structural Rating
764
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
764
Pipe schematic from manhole B 0013 to B 0012
MH: B 0013MH: B 0012downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - B 00132 ft. MGO - General Observation - MAG COATING THROUGHOUT2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start140.3 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1039.9 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish1039.9 ft. AMH - Downstream Manhole, Survey Ends - B 0012 ZOOMED IN

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (9)

DistanceCodeObservation
2MGOMAG COATING THROUGHOUT
1039.9SAV
1039.9AMHB 0012 ZOOMED IN
2SAV
0MWL
2SRV
140.3SRV
0MWM
0AMHB 0013

Properties (8)

additional_info
630098012622051
custom_field_three
SURFACE REINFORCEMENT VISIBLE/SPALLING
custom_field_two
2
customer
1
datetime
2022-01-26T08:31:43-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
36930