Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jan 28, 2022, 08:38 PM
  • B 0003_B 0002_01282022_124351.mp4

Date
01/28/2022
W/O
926981
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00072
PipeID
P08513
Time
12:38 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9587
Sewer Name
B JOINT OUTFALL B - UNIT 1A
City
CARSON
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_926981_TV08132_DEC2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
144 in.
Width
33 in.
Upstream MH
B 0003
Downstream MH
B 0002
Dir. of Survey
Downstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
5
Structural Quick
5100
Structural Rating
5
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
5
Overall Quick
Overall Rating
5
Pipe schematic from manhole B 0003 to B 0002
MH: B 0003MH: B 0002downstream0 ft. AMH - Upstream Manhole, Survey Begins - B 00030 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 45 %of cross sectional area2 ft. SRC - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES - BROKEN REBAR2 ft. MGO - General Observation - REINFORCEMENT OBSTRUCTING FLOW2 ft. MSA - Survey Abandoned - CAMERA BLKD BY SURFACE REINFORCEMENT

Observation photos (3)

  • Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES - BROKEN REBAR

    2 ft. - Surface Reinforcement Corroded, from 08 to 04 o'clock, within 8 inches of joint: YES - BROKEN REBAR

  • General Observation - REINFORCEMENT OBSTRUCTING FLOW

    2 ft. - General Observation - REINFORCEMENT OBSTRUCTING FLOW

  • Survey Abandoned - CAMERA BLKD BY SURFACE REINFORCEMENT

    2 ft. - Survey Abandoned - CAMERA BLKD BY SURFACE REINFORCEMENT

Observations (6)

DistanceCodeObservation
2SRCBROKEN REBAR
2MGOREINFORCEMENT OBSTRUCTING FLOW
0AMHB 0003
0MWL
0MWM
2MSACAMERA BLKD BY SURFACE REINFORCEMENT

Properties (8)

additional_info
630098012822061
custom_field_three
REBAR HANGING IN PIPE
custom_field_two
1
customer
1
datetime
2022-01-28T12:38:34-08:00
documentation
PRO PIPE
is_lateral_inspection
false
year_laid
36930