- Date
- 12/27/2021
- W/O
- 926598
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00156
- PipeID
- P10023
- Time
- 9:11 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K9572
- Sewer Name
- D JOINT OUTFALL D - UNIT 6
- City
- REDONDO BEACH
- Loc. details
- Parking Lot
- Location Code
- G
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 16
- Purpose
- Routine Assessment
- Project
- RFIR_WO_926598_TV05172_DEC2021
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 33 in.
- Width
- 30 in.
- Upstream MH
- D 0115
- Downstream MH
- D 0114
- Dir. of Survey
- Downstream
- Length Surveyed
- 542.3 ft.
- Total Length
- 542.3 ft.
- Structural Index
- 3
- Structural Quick
- 523T
- Structural Rating
- 333
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 333
Pipe schematic from manhole D 0115 to D 0114 Observation photos (4)

2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

156.1 ft. - Surface Reinforcement Visible, from 11 to 01 o'clock, within 8 inches of joint: NO

259.7 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start