Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 29, 2021, 06:17 AM
  • D 0097_D 0096_12282021_223014.mp4

Date
12/28/2021
W/O
926598
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00156
PipeID
P10003
Time
10:17 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K9574
Sewer Name
D JOINT OUTFALL D - UNIT 6
City
LAWNDALE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_926598_TV05172_DEC2021
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
33 in.
Width
57 in.
Upstream MH
D 0097
Downstream MH
D 0096
Dir. of Survey
Downstream
Length Surveyed
313.9 ft.
Total Length
313.9 ft.
Structural Index
3
Structural Quick
5K3K
Structural Rating
615
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
615
Pipe schematic from manhole D 0097 to D 0096
MH: D 0097MH: D 0096downstream0 ft. AMH - Upstream Manhole, Survey Begins - D 00970 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT THE MH 3 OC'LOCK CAPPED2.5 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.5 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start8.4 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start306 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"311.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish311.2 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish311.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish313.9 ft. MGO - General Observation - CONNECTION AT THE MH 9 OC'LOCK CAPPED313.9 ft. AMH - Downstream Manhole, Survey Ends - D 0096

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.5 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    8.4 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
311.2SAP
8.4SRV
0AMHD 0097
306TF
0MGOCONNECTION AT THE MH 9 OC'LOCK
313.9MGOCONNECTION AT THE MH 9 OC'LOCK CAPPED
311.2SRV
0MWL
2.5SAP
0MWM
0MGOCONNECTION AT THE MH 3 OC'LOCK CAPPED
2.5SSS
313.9AMHD 0096
311.2SSS

Properties (7)

additional_info
630074122821201
custom_field_three
AGGREGATE PROJECTING/REINFORCEMENT VISBLE/SPALLING
custom_field_two
2
customer
1
datetime
2021-12-28T22:17:15-08:00
documentation
PROPIPE
is_lateral_inspection