- Date
- 02/07/2022
- W/O
- 0931911
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00691
- PipeID
- P14346
- Time
- 3:21 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H3005
- Sewer Name
- 18 NORTH PLANT OUTFALL TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 14
- Purpose
- Capital Improvement Program Assesment
- Project
- 20220203MDM_NORTH_PLANT_OUTFALL_TRUNK
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 16 in.
- Upstream MH
- 18 0492
- Downstream MH
- 18 0491
- Dir. of Survey
- Downstream
- Length Surveyed
- 32.9 ft.
- Total Length
- 32.9 ft.
- Structural Index
- 3
- Structural Quick
- 5141
- Structural Rating
- 17
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 17
Pipe schematic from manhole 18 0492 to 18 0491 Observation photos (6)

5.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - SL

31.9 ft. - Repair Patch, from 02 to 10 o'clock, within 8 inches of joint: YES - MISSING PIPE INCASED

31.9 ft. - Repair Patch, from 02 to 10 o'clock, within 8 inches of joint: YES - MISSING PIPE INCASED

31.9 ft. - Repair Patch, from 02 to 10 o'clock, within 8 inches of joint: YES - MISSING PIPE INCASED

32.3 ft. - Broken, from 10 to 02 o'clock, within 8 inches of joint: YES - OFFSET

32.9 ft. - Survey Abandoned - INCASED MISSING PIPE AREA(WILL COMPLERTE REVERESE INSPECTION